Brand, Models, CGM integration ; Medtronic, 1. 670G 2. 630G 3. 530G 4. Paradigm 5. Revel, 1. Yes—Guardian 2. Yes—Enlite 3. Yes—Enlite 4. No 5. No ; Tandem, 1. T:slim 2. T:slim G4 3. T:slim X2 4. T:flex, 1. No 2. Yes—Dexcom G4 3. Yes—Dexcom G5 4. No ; Insulet, Omnipod, No ; Roche, Accu-Chek Spirit, No ; Animas, 1. OneTouch Ping 2. Animas Vibe, 1. No 2. Yes ; Sooil, Dana Diabecare IIS, No
3 U, using either an insulin pump or multiple daily injections with carbohydrate counting, completed two randomized crossover 48-h visits at the University of Virginia, wearing Dexcom G4...
Description ; This application is a continuation of application Ser. No. 12/774,991 filed May 6, 2010, which in turn is a continuation application Ser. No. 11/753,420 filed May 24, 2007, now U.S. Pat. No. 7,751,907 issued Jul. 6, 2010, each of which is hereby fully incorporated herein by reference. The field generally relates to patient insulin management devices and, in particular, but not by way of limitation, to systems, devices and methods for managing insulin therapy. People who suffer from diabetes require insulin to keep their blood gluc ...
the arduino board is connected to a "contour plus" glucometer that can remotly inject insulin in metronic insulin pumps. the connection between the components is strait ford, the main issue...
Description ; This application is a continuation of application Ser. No. 12/908,218 filed Oct. 20, 2010, which in turn is a division of application Ser. No. 11/970,232 filed Jan. 7, 2008, which is hereby fully incorporated herein by reference. People who suffer from diabetes require insulin to keep their blood glucose level as close as possible to normal levels. It is essential for people with diabetes to manage their blood glucose level to within a normal range. Complications from diabetes can include heart disease (cardiovascular disease), bl ...
An apparatus comprising a pump configured to deliver insulin, an input configured to receive blood glucose data, a user interface, and a controller communicatively coupled to the pump, the input, a...
A Cause for Unexplained High Glucoses (UHGs) on a Pump ; Today’s infusion sets offer many improvements and options, yet reports and blogs suggest issues with infusion sets are widespread. Only a handful of studies have directly looked at this problem.1 Infusion set leaks and failures create random unexplained high glucose values (UHGs). They also make up most phone calls to manufacturers and end up being a common reason that people stop wearing a pump. The Weak Spots graphic shows all the ways you can lose insulin, but nearly all UHGs arise f ...
Description ; This application is a continuation of application Ser. No. 11/018,706 filed Dec. 20, 2004, which in turn is a continuation of application Ser. No. 10/086,641 filed Feb. 28, 2002, now U.S. Pat. No. 6,852,104 issued Feb. 8, 2005, each of which is hereby fully incorporated herein by reference. This application incorporates by reference the disclosures of the following applications: U.S. application Ser. No. 10/086,646 filed Feb. 28, 2002, now U.S. Pat. No. 7,033,338 issued Apr. 25, 2006, entitled CARTRIDGE AND ROD FOR AXIALLY LOADING ...
In a randomized, three-period cross-over study, twelve adults with insulin-pump-treated type 1 diabetes followed an HC (energy provided by carbohydrate: 48%, fat: 33%, protein: 19%), HF (19...
, Dexcom G6, Dexcom G7, Guardian Sensor 3 ; Company, Dexcom, Dexcom, Medtronic ; Size, mm, 45×30×15, 27.3×24×4.6, 35×28×9.5 ; FDA approved year, 2018, Awaiting, 2018 ; Approved age, ≥2 years, ≥2 years, ≥2 years ; Sensor type, Real-time, Real-time, Real-time ; Wear time, 10 days, 10.5 days, 7 days ; Warm-up period, 2 hours, 27 minutes, 2 hours ; Calibration required, No, No, Yes (2 times/day) ; Alarms for hypo/hyperglycemia, Yes, Yes (can be delayed up to 6 hours), Yes ; Integrity with insulin pumps, Yes, Yes, Yes ; Platform, Dexcom clarity, Dexcom clarity, CareLink Personal ; Accuracy (MARD), 10.0%, 8.2% (arm), 9.1% (abdomen), 8.7% (arm), 9.6% (abdomen) ; Accuracy in low glucose range (MAD), 10.9 mg/dL (glucose level <54 mg/dL), 8.5 mg/dL (arm), 10.3 mg/dL (abdomen) (glucose level 40–60 mg/dL), NA ; Bluetooth free range, 6 m, 6 m, 6 m