Vapour pressure of water

breathing and cavitation. Contents 1 Approximation formulas 1.1 Accuracy of different... of equations for temperatures above and below freezing, with different levels of accuracy. They are...

IEER Explained: Integrated Energy Efficiency Ratio (vs EER, SEER)

IEER Eq. Symbol:, Outdoor Temp.:, Load:, EER: ; A, 95.0°F, 100%, 11.0 ; B, 81.5°F, 75%, 13.9 ; C, 68.0°F, 50%, 18.4 ; D, 65.0°F, 25%, 19.1

Thermal conductance and resistance

Heat exchangers: In industries like HVAC and chemical processing, heat exchangers use thermal conductance to efficiently transfer heat between fluids. Aerospace: In spacecraft and aircraft...

Coefficient of variation

In probability theory and statistics, the coefficient of variation (CV), also known as... Some formulas in these fields are expressed using the squared coefficient of variation , often...

Piping Equations

A i = cross-sectional inside area of pipe (m 2, in2) ; A m = cross-sectional wall area of pipe (m 2, in2) ; w p = weight of empty pipe per unit length (kg/m, lb/in) ; w l = weight of liquid in pipe per unit length of pipe (kg, lb)

Cooling and Heating Equations

Sensible Heat ; The sensible heat in a heating or cooling process of air (heating or cooling capacity) can be calculated in SI-units as · h s = cp ρ q dt (1) · where · h s = sensible heat (kW) · c p = specific heat of air (1.006 kJ/kg oC) · ρ = density of air (1.202 kg/m 3 ) · q = air volume flow (m 3 /s) · dt = temperature difference ( oC) · Or in Imperial units as · h s = 1.08 q dt (1b) · where · h s = sensible heat (Btu/hr) · q = air volume flow (cfm, cubic feet per minute) · dt = temperature difference ( oF) · Metric Units

HVAC Abbreviations

ATC - automatic temperature control, at ceiling ; DB - dry bulb ; MBH - thousand British thermal units per hour

sequences and series - Creating a repeating numerical pattern using a formula -

org/ (-12 + 13*x)/(1 - x)^2 then add a Mod to limit the range between -12 and 12 somehow. I tried the formula from https://oeis.org/ (-12 + 13*x)/(1 - x)^2 but when I create the formula in...

Pipe and Tubing Formulas

Moment of inertia can be expressed as ; where · I = moment of inertia (in 4) · d o = outside diameter (in) · d i = inside diameter (in)

Educator's Resources

The expertise of its worldwide membership and the results of society-funded research give ASHRAE publications a depth and breadth unmatched by commercial publishers. Your students will appreciate the depth of information and low prices of these texts. Adopt one of these authoritative and timely books for your course: Principles of Heating, Ventilating, and Air Conditioning, Ninth Edition, is a textbook based on content from all four volumes of the ASHRAE Handbook, pulli ...